Plain English summary not yet available
The full original text is available below. Check back soon as we process this bill.
IIB
116TH CONGRESS
2D SESSION
H. R. 5758
IN THE SENATE OF THE UNITED STATES
DECEMBER 10, 2020
Received; read twice and referred to the Committee on Energy and Natural
Resources
AN ACT
To amend the Energy Policy and Conservation Act to make
technical corrections to the energy conservation standard
for ceiling fans, and for other purposes.
Be it enacted by the Senate and House of Representa-
1
tives of the United States of America in Congress assembled,
2
VerDate Sep 11 2014
02:01 Dec 11, 2020
Jkt 019200
PO 00000
Frm 00001
Fmt 6652
Sfmt 6201
E:\BILLS\H5758.RFS
H5758
pbinns on DSKJLVW7X2PROD with BILLS
2
HR 5758 RFS
SECTION 1. SHORT TITLE.
1
This Act may be cited as the ‘‘Ceiling Fan Improve-
2
ment Act of 2020’’.
3
SEC. 2. MODIFICATIONS TO THE CEILING FAN ENERGY
4
CONSERVATION STANDARD.
5
(a) IN GENERAL.—Section 325(ff)(6) of the Energy
6
Policy and Conservation Act (42 U.S.C. 6295(ff)(6)) is
7
amended by adding at the end the following:
8
‘‘(C)(i) Large-diameter ceiling fans manufactured on
9
or after January 21, 2020, shall—
10
‘‘(I) not be required to meet minimum ceiling
11
fan efficiency in terms of ratio of the total airflow
12
to the total power consumption as described in the
13
final rule titled ‘Energy Conservation Program: En-
14
ergy Conservation Standards for Ceiling Fans’ (82
15
Fed. Reg. 6826 (January 19, 2017)); and
16
‘‘(II) have a CFEI greater than or equal to—
17
‘‘(aa) 1.00 at high speed; and
18
‘‘(bb) 1.31 at 40 percent speed or the
19
nearest speed that is not less than 40 percent
20
speed.
21
‘‘(ii) For purposes of this subparagraph, the term
22
‘CFEI’ means the Fan Energy Index for large-diameter
23
ceiling fans, calculated in accordance with ANSI/AMCA
24
Standard 208–18 titled ‘Calculation of the Fan Energy
25
Index’, with the following modifications:
26
VerDate Sep 11 2014
02:01 Dec 11, 2020
Jkt 019200
PO 00000
Frm 00002
Fmt 6652
Sfmt 6201
E:\BILLS\H5758.RFS
H5758
pbinns on DSKJLVW7X2PROD with BILLS
3
HR 5758 RFS
‘‘(I) Using an Airflow Constant (Q0) of 26,500
1
cubic feet per minute.
2
‘‘(II) Using a Pressure Constant (P0) of 0.0027
3
inches water gauge.
4
‘‘(III) Using a Fan Efficiency Constant (η0) of
5
42 percent.’’.
6
(b) REVISION.—For purposes of section 325(m) of
7
the Energy Policy and Conservation Act (42 U.S.C.
8
6295(m)),
the
standard
established
in
section
9
325(ff)(6)(C) of such Act (as added by subsection (a) of
10
this section) shall be treated as if such standard was
11
issued on January 19, 2017.
12
Passed the House of Representatives December 9,
2020.
Attest:
CHERYL L. JOHNSON,
Clerk.
VerDate Sep 11 2014
02:01 Dec 11, 2020
Jkt 019200
PO 00000
Frm 00003
Fmt 6652
Sfmt 6201
E:\BILLS\H5758.RFS
H5758